ConnectMQ Edge

From PLC to cloud, without writing a line of code

ConnectMQ Edge is a Windows gateway that collects data from PLCs, Modbus meters, protection relays, OPC UA servers and local brokers, sends it securely to your ConnectMQ broker in a clean ISA-95 topic structure, and keeps it on disk while the internet is down.

No card required

  • 10 drivers
  • Offline buffer
  • Local OPC UA & MQTT
  • Windows service

Connect field devices without code

Pick a template — Siemens S7, OMRON, Modbus, OPC UA, IEC 104 or IEC 61850 — set the IP address and tags, and press Save and apply. The channel starts right away; the service does not restart.

A clean ISA-95 topic tree

Every tag arrives as enterprise/site/area/line/cell/device/tag with a JSON payload — value, quality, unit and timestamp — ready for dashboards, alerts and the Digital Twin.

Keeps data when the line drops

If the internet connection goes down, Edge buffers readings on disk and sends them to ConnectMQ Cloud when the link is back — no gaps in your history.

Serves the plant locally, too

Everything Edge collects is also available on its own OPC UA server (:48010) and local MQTT broker (:1883), so SCADA, MES and historians read one endpoint instead of many protocols.

Quick setup

Up and running in six steps

  1. 1

    Install

    Run the setup as administrator: one installer adds the Windows service and the desktop app.

  2. 2

    Sign in

    Use your ConnectMQ account — Google, LinkedIn or e-mail.

  3. 3

    Pick credentials

    Select the broker credential set Edge should use, if you have more than one.

  4. 4

    Check status

    The tray icon turns green and the ONLINE strip shows the connection to ConnectMQ Cloud.

  5. 5

    Add connectors

    Add a channel per PLC, meter or server from a template — or start with the Simulator for a quick test.

  6. 6

    Use the data

    The topics appear in the ConnectMQ portal, ready for dashboards, alerts and the Digital Twin.

Get ConnectMQ Edge

ConnectMQ Edge is included in the Basic and Scale plans. Sign in to the ConnectMQ portal and download the installer from the ConnectMQ Edge page in your account menu.

  • Windows 10 / 11 · Windows Server 2016+ (x64)
  • Windows service + desktop app, one installer
  • Sign in with your ConnectMQ account

ConnectMQ Edge: frequently asked questions

What is ConnectMQ Edge?

A Windows gateway that runs next to your machines. It reads PLCs, meters, relays and OPC UA servers, turns the values into MQTT messages in an ISA-95 topic tree and sends them to your ConnectMQ broker over TLS.

What happens when the internet connection drops?

Edge keeps collecting and stores the readings on disk. When the connection is back, the buffered data is sent to ConnectMQ Cloud, so your history has no gaps.

Can my local SCADA read the data too?

Yes. Edge runs its own OPC UA server on port 48010 and a local MQTT broker on port 1883. Local SCADA, HMI, MES or historians can read every tag from Edge without going through the cloud.

Which plans include ConnectMQ Edge?

ConnectMQ Edge is included in the Basic and Scale plans. You download it from your ConnectMQ account after signing in.

Connect your first PLC this week

Create your ConnectMQ account, download ConnectMQ Edge from the portal and add your first connector in minutes.