ConnectMQ Edge · OPC UA Client

Any OPC UA server, connected to the cloud

Most modern PLCs, SCADA systems and gateways already speak OPC UA, but getting that data to the cloud securely still takes work. ConnectMQ Edge subscribes to any OPC UA server, transfers only changes and publishes them to your ConnectMQ broker as clean ISA-95 topics, ready for dashboards, alerts and the Digital Twin. It is also the way to bring optimized S7-1500 data blocks to the cloud.

  • opc.tcp:// · subscriptions
  • S7-1500, Beckhoff, B&R
  • KEPServerEX, other servers

No card required

Why connect OPC UA Client to ConnectMQ

Only changes, no constant polling

Values arrive by subscription, so only changes travel from the server to Edge and on to ConnectMQ.

Tags discovered for you

Point a device at a BrowseRoot with AutoCreateTags, and Edge creates a tag for every variable below that node.

Secure from server to cloud

Sign or SignAndEncrypt with user login towards the server, MQTT over TLS (port 8883) to ConnectMQ, and an offline disk buffer in between.

What it reads and does

  • Any OPC UA server: S7-1500, Beckhoff, B&R, KEPServerEX, another Edge
  • Subscriptions: only changed values are transferred
  • Nodes listed by NodeId or discovered below a BrowseRoot
  • SecurityMode Sign / SignAndEncrypt with user name and password
  • Optimized S7-1500 data blocks via the PLC’s OPC UA server
What arrives in ConnectMQ Cloudconnectmq/site1/production/line1/press/Press1/Pressure
{ "value": 182.6, "quality": "good", "unit": "bar", "tag": "Pressure", "device": "Press1", "channel": "LineUa" }

Up and running in three steps

  1. 1

    Install ConnectMQ Edge

    Download Edge from your ConnectMQ account and sign in — the Windows service and desktop app come in one installer.

  2. 2

    Add the OPC UA Client channel

    Pick the OPC UA Client template, enter the address of your device and the tags you need, and press Save and apply.

  3. 3

    Use the data

    The tags appear in your ConnectMQ broker as ISA-95 topics, ready for dashboards, alerts and the Digital Twin.

Where teams use it

Optimized S7-1500 data

Read symbolic data blocks of S7-1500 PLCs through their built-in OPC UA server and use them in ConnectMQ dashboards and alerts.

SCADA and KEPServerEX to the cloud

Bring tags you already have in KEPServerEX or another OPC UA server into ConnectMQ without touching the field devices.

Multi-vendor lines

Combine Beckhoff, B&R and Siemens machines in one ISA-95 tree and compare them on the same dashboards.

OPC UA Client: frequently asked questions

How do I send OPC UA data to MQTT?

Add an OPC UA Client channel in ConnectMQ Edge, enter the server’s endpoint URL (for example opc.tcp://192.168.1.50:4840) and, if required, a user name and password, then list the nodes as tags or let Edge browse them. Edge subscribes to the nodes and publishes the values to your ConnectMQ broker over MQTT and TLS (port 8883) in an ISA-95 topic tree.

Do I have to add every OPC UA node by hand?

No. Give a device "AutoCreateTags": true and a BrowseRoot (for example ns=3;s=Press1), and Edge creates a tag for every variable below that node; BrowseDepth sets how deep it browses. You can also list single nodes as tags, for example ns=3;s="DB_Press"."Pressure" copied from UaExpert.

Does the OPC UA Client support encrypted connections?

Yes. Set SecurityMode to Sign or SignAndEncrypt and, if the server requires it, a user name and password. Then trust the Edge client certificate on the server; it is created in %ProgramData%\ConnectMQ\Edge\pki-client\own.

Technical details: step-by-step setup and example configuration

Set it up step by step

  1. 1

    Get the endpoint URL of the server (for example opc.tcp://192.168.1.50:4840) and, if required, a user name and password.

  2. 2

    In ConnectMQ Edge, open Connectors in the left menu, click + Add channel and pick the OPC UA Client template.

  3. 3

    The channel is added with sample addresses. In the editor on the right, change the endpoint URL, device settings and tags to match your equipment; Validate project checks the configuration.

  4. 4

    Press Save and apply. The channel starts right away without restarting the service. Add as many channels as you need, including several of the same type.

  5. 5

    Either list the nodes as tags (ns=3;s="DB_Press"."Pressure", copied from UaExpert) or let Edge discover them: a device with "AutoCreateTags": true and a BrowseRoot creates a tag for every variable below that node.

  6. 6

    With SecurityMode Sign or SignAndEncrypt, trust the Edge client certificate on the server. It is created in %ProgramData%\ConnectMQ\Edge\pki-client\own.

  7. 7

    Check the result: on Overview, the devices show Reading data under Field devices, and problems (wrong address, timeout, rejected login) appear in the Last problem column. The values themselves are in Local OPC UA Server › Live tag values; details are in Windows Service Settings › Logs.

  8. 8

    Open the ConnectMQ portal: the tags appear in the topic tree as <enterprise>/<site>/<area>/<line>/<cell>/<device>/<tag> with a JSON payload (value, quality, unit, timestamp), ready for dashboards, alerts and the Digital Twin.

Example configuration
{
  "Name": "LineUa",
  "Driver": "OpcUaClient",
  "Settings": {
    "EndpointUrl": "opc.tcp://192.168.1.50:4840",
    "SecurityMode": "SignAndEncrypt",
    "Username": "operator",
    "Password": "***"
  },
  "Devices": [
    {
      "Name": "Press1",
      "ScanRateMs": 500,
      "Tags": [
        { "Name": "Pressure", "Address": "ns=3;s=\"DB_Press\".\"Pressure\"", "Unit": "bar" }
      ]
    },
    {
      "Name": "AllVariables",
      "Settings": { "BrowseRoot": "ns=3;s=Press1", "BrowseDepth": 3, "AutoCreateTags": true }
    }
  ]
}

Good to know

  • Values arrive by subscription, so only changes are transferred between the OPC UA server and Edge.
  • Optimized (symbolic) S7-1500 data blocks cannot be read with the Siemens S7 connector; read them through the S7-1500 OPC UA server with this connector instead.
  • If the connection fails with Sign or SignAndEncrypt, the server most likely does not trust the Edge client certificate yet. You find it in %ProgramData%\ConnectMQ\Edge\pki-client\own.

Connect your first PLC this week