RTU and substation data usually stays locked inside a local SCADA. ConnectMQ Edge acts as the IEC 60870-5-104 controlling station, receives spontaneous data and general interrogation responses, and sends every signal to your ConnectMQ broker as clean ISA-95 JSON — ready for dashboards, alerts and the Digital Twin, right next to your plant data.
Download Edge from your ConnectMQ account and sign in — the Windows service and desktop app come in one installer.
2
Add the IEC 60870-5-104 channel
Pick the IEC 60870-5-104 template, enter the address of your device and the tags you need, and press Save and apply.
3
Use the data
The tags appear in your ConnectMQ broker as ISA-95 topics, ready for dashboards, alerts and the Digital Twin.
Where teams use it
Substation monitoring
Breaker states, active power and alarms from every substation on one ConnectMQ dashboard, with alerts when a breaker changes state.
Remote feeders in one view
Bring RTU data from distributed feeders and sites into one ISA-95 topic tree instead of separate local screens.
Setpoints from an approved system
Let your own approved application write power setpoints through Edge, using select-before-operate where the RTU expects it.
IEC 60870-5-104: frequently asked questions
How do I connect an IEC 60870-5-104 RTU to MQTT?
Install ConnectMQ Edge on a Windows PC that can reach the RTU on port 2404, add an IEC 60870-5-104 channel, enter the IP address, common address and IOAs, and press Save and apply. Edge publishes every signal to your ConnectMQ broker over MQTT/TLS as ISA-95 topics with JSON payloads.
Can ConnectMQ Edge send IEC 104 commands and setpoints?
Yes. Mark the tag Writable and set Command (single, double, setpoint_float…) and, if needed, CommandAddress. Edge acts as the controlling station and uses select-before-operate where the RTU requires it.
Do I have to configure every IOA by hand?
No. With "AutoCreateTags": true Edge creates a tag for every IOA the RTU sends. Otherwise each tag in the configuration is one IOA.
Technical details: step-by-step setup and example configuration
Set it up step by step
1
Get the RTU IP address (port 2404), the common address (ASDU address) and the IOA list of the signals.
2
In ConnectMQ Edge open Connectors in the left menu, click + Add channel and pick the IEC 60870-5-104 template.
3
The channel is added with sample addresses. In the editor on the right, change the IP address, device settings and tags to match your equipment — the example configuration shows the format. Validate project checks it.
4
Press Save and apply. The channel starts right away without restarting the service. Add as many channels as you need, including several of the same type.
5
Each device is one common address and each tag is one IOA (for example 4001). Use "AutoCreateTags": true to create a tag for every IOA the RTU sends.
6
For commands, mark the tag Writable and set Command (single, double, setpoint_float…) and, if it differs, CommandAddress.
7
Check the result: on Overview the devices show Reading data under Field devices, and problems (wrong address, timeout, rejected login) appear in the Last problem column. The values are in Local OPC UA Server › Live tag values; details are in Windows Service Settings › Logs.
8
Open the ConnectMQ portal: the tags appear in the topic tree as <enterprise>/<site>/<area>/<line>/<cell>/<device>/<tag> with a JSON payload (value, quality, unit, timestamp), ready for dashboards, alerts and the Digital Twin.
Sparkplug B gives industrial MQTT a strict session and payload model, while a Unified Namespace gives your plant data a single, readable home. Here is how they fit together, with topic design tips and live examples.
A practical 12-point checklist for choosing an IoT MQTT broker, a table of questions to ask every vendor, and a five-minute hands-on test you can run against broker.connectmq.com.
A hands-on MQTT security checklist covering TLS, credentials, client IDs, topic design, payload validation, rate limits and certificate checks, plus how ConnectMQ handles each point.