# Your OMRON PLCs, streaming to the cloud

Many lines run on a mix of CJ, CP and CS PLCs and newer NJ/NX controllers, and each speaks a different language. ConnectMQ Edge reads FINS memory areas and NJ/NX variables by name, without custom code, and sends every value to your ConnectMQ broker as clean ISA-95 data for dashboards, alerts and the Digital Twin. Values are buffered on disk while the internet is down.

-   FINS/TCP or UDP · port 9600
-   CJ / CP / CS
-   NJ / NX over EtherNet/IP

[Try it free](https://app.connectmq.com/signup) [See pricing](https://connectmq.com/pricing/)

No card required

-   Siemens S7 PLCs
-   OMRON PLCs
-   Modbus meters
-   IEC 104 RTUs
-   IEC 61850 IEDs
-   OPC UA servers

**ConnectMQ Edge**Windows service`ISA-95 · JSON``offline buffer`SCADA / HMI · OPC UA :48010 · MQTT :1883

**ConnectMQ Cloud**`broker.connectmq.com`Dashboards · Alerts · Digital Twin · API

## Why connect OMRON FINS / NJ-NX to ConnectMQ

### Old and new OMRON in one place

Two drivers side by side: FINS for CJ/CP/CS memory areas and EtherNet/IP for NJ/NX variables, all in the same ISA-95 topic tree.

### Variables by name, not by address

On NJ/NX, read Motor.Speed or Values\[3\] directly from published global variables, with no memory map to maintain.

### Ready for ConnectMQ, safe offline

Tags arrive with value, quality, unit and timestamp for dashboards and alerts, and wait on disk if the internet drops.

## What it reads and does

-   CJ, CP and CS PLCs over FINS/TCP or FINS/UDP (port 9600)
-   Memory areas DM, CIO, W, H, EM…: D100, CIO0.00, E0\_100
-   NJ/NX global variables by name over EtherNet/IP
-   Structure members, array elements and bits: Motor.Speed, Values\[3\], StatusWord.5
-   FINS/TCP with no node settings

What arrives in ConnectMQ Cloud`connectmq/site1/production/line2/packing/CJ2M/Temperature`

```
{ "value": 71.4, "quality": "good", "unit": "°C", "dataType": "Float32", "tag": "Temperature", "device": "CJ2M", "channel": "PackingFins" }
```

## Up and running in three steps

1.  1
    
    ### Install ConnectMQ Edge
    
    Download Edge from your ConnectMQ account and sign in — the Windows service and desktop app come in one installer.
    
2.  2
    
    ### Add the OMRON FINS / NJ-NX channel
    
    Pick the OMRON FINS / NJ-NX template, enter the address of your device and the tags you need, and press Save and apply.
    
3.  3
    
    ### Use the data
    
    The tags appear in your ConnectMQ broker as ISA-95 topics, ready for dashboards, alerts and the Digital Twin.
    

## Where teams use it

### Packaging and assembly dashboards

Stream counters, run states and temperatures from packaging and assembly lines into live production dashboards in ConnectMQ.

### Mixed fleets, one view

Bring older CJ machines and new NX lines into the same ISA-95 tree, so every line is reported the same way.

### Process alerts

Set ConnectMQ rules on temperatures or stop states and notify the right team as soon as a line drifts.

## OMRON FINS / NJ-NX: frequently asked questions

How do I connect an OMRON CJ2M PLC to MQTT?

Add an OMRON FINS channel in ConnectMQ Edge, enter the PLC IP address (port 9600) and list the tags with memory addresses such as D100 or CIO0.00. FINS/TCP needs no node settings. After Save and apply, Edge publishes the values to your ConnectMQ broker over MQTT and TLS (port 8883) in an ISA-95 topic tree.

Can ConnectMQ Edge read OMRON NJ/NX variables by name?

Yes. The OmronNj driver reads NJ/NX global variables by name over EtherNet/IP, for example Motor.Speed, Values\[3\] or StatusWord.5. In Sysmac Studio, set Network Publish to “Publish Only” (or Input/Output) for each variable and transfer the project to the PLC.

Does the OMRON connector use FINS/TCP or FINS/UDP?

Both, on port 9600. FINS/TCP is the default and needs no node settings. For FINS/UDP set "Protocol": "Udp"; the node numbers are taken from the IP addresses.

Technical details: step-by-step setup and example configuration

### Set it up step by step

1.  1
    
    For FINS: note the PLC IP address. FINS/TCP needs no node settings; for FINS/UDP set "Protocol": "Udp" (node numbers are taken from the IP addresses).
    
2.  2
    
    For NJ/NX: in Sysmac Studio, set Network Publish to “Publish Only” (or Input/Output) for each global variable you want to read, then transfer to the PLC.
    
3.  3
    
    In ConnectMQ Edge, open Connectors in the left menu, click + Add channel and pick the OMRON FINS or OMRON NJ/NX template.
    
4.  4
    
    The channel is added with sample addresses. In the editor on the right, change the IP address, device settings and tags to match your equipment; Validate project checks the configuration.
    
5.  5
    
    Press Save and apply. The channel starts right away without restarting the service. Add as many channels as you need, including several of the same type.
    
6.  6
    
    Enter the addresses. FINS uses memory addresses such as D100, CIO0.00, H10, E0\_100 or T5.F; NJ/NX uses variable names such as Motor.Speed, Values\[3\] or StatusWord.5.
    
7.  7
    
    Check the result: on Overview, the devices show Reading data under Field devices, and problems (wrong address, timeout, rejected login) appear in the Last problem column. The values themselves are in Local OPC UA Server › Live tag values; details are in Windows Service Settings › Logs.
    
8.  8
    
    Open the ConnectMQ portal: the tags appear in the topic tree as <enterprise>/<site>/<area>/<line>/<cell>/<device>/<tag> with a JSON payload (value, quality, unit, timestamp), ready for dashboards, alerts and the Digital Twin.
    

Example configuration

```
{
  "Name": "PackingFins",
  "Driver": "OmronFins",
  "Devices": [{
    "Name": "CJ2M",
    "Isa95": { "Line": "line2", "Cell": "packing" },
    "Settings": { "Host": "192.168.250.1", "Port": 9600 },
    "Tags": [
      { "Name": "Counter", "Address": "D100", "DataType": "UInt16" },
      { "Name": "Running", "Address": "CIO0.00" },
      { "Name": "Temperature", "Address": "D200", "DataType": "Float32", "Unit": "°C" }
    ]
  }]
},
{
  "Name": "AssemblyNj",
  "Driver": "OmronNj",
  "Devices": [{
    "Name": "NX1P2",
    "Settings": { "Host": "192.168.250.10", "Path": "1,0" },
    "Tags": [
      { "Name": "MotorSpeed", "Address": "Motor.Speed", "DataType": "Float32", "Unit": "rpm" }
    ]
  }]
}
```

### Good to know

-   NJ/NX variables are read by name only if Network Publish is set to “Publish Only” or Input/Output in Sysmac Studio and the project has been transferred to the PLC.
-   FINS/TCP needs no node settings. With FINS/UDP ("Protocol": "Udp"), node numbers are taken from the IP addresses.
-   Both drivers can run side by side: use one OMRON FINS channel for CJ/CP/CS PLCs and one OMRON NJ/NX channel for NJ/NX controllers, as in the example.

## Other connectors

[**Siemens S7**S7-1200/1500, S7-300/400, S7-200 SMART and LOGO! over ISO-on-TCPLearn more](https://connectmq.com/connectmq-edge/siemens-s7/) [**Modbus TCP / RTU**Energy meters, drives and PLCs over Modbus TCP, UDP or RS-485 RTULearn more](https://connectmq.com/connectmq-edge/modbus/) [**OPC UA Client**Subscribe to any OPC UA server: S7-1500, Beckhoff, B&R, KEPServerEXLearn more](https://connectmq.com/connectmq-edge/opc-ua-client/) [**IEC 60870-5-104**RTUs and substation gateways as controlling station, port 2404Learn more](https://connectmq.com/connectmq-edge/iec-104/) [**IEC 61850 (MMS)**Protection relays, bay controllers and IEDs over MMS with SCL importLearn more](https://connectmq.com/connectmq-edge/iec-61850/) [**Sparkplug B**Ignition, Node-RED and Sparkplug gateways via the local brokerLearn more](https://connectmq.com/connectmq-edge/sparkplug-b/) [**Local OPC UA server**Every tag Edge collects on one OPC UA endpoint for SCADA and MESLearn more](https://connectmq.com/connectmq-edge/opc-ua-server/)

[ConnectMQ Edge](https://connectmq.com/connectmq-edge/)

## Connect your first PLC this week

Create your ConnectMQ account, download ConnectMQ Edge from the portal and add your first connector in minutes.

[Get started](https://app.connectmq.com/signup) [See pricing](https://connectmq.com/pricing/)

## Articles

[All articles](https://connectmq.com/blog/)

Industrial IoT

### [Sparkplug B and the Unified Namespace: Structuring Industrial IoT Data on MQTT](https://connectmq.com/blog/mqtt-sparkplug-b-unified-namespace/)

Sparkplug B gives industrial MQTT a strict session and payload model, while a Unified Namespace gives your plant data a single, readable home. Here is how they fit together, with topic design tips and live examples.

August 26, 20269 min read

Managed MQTT Cloud

### [How to Choose an IoT MQTT Broker: 12 Criteria and the Questions to Ask Your Vendor](https://connectmq.com/blog/how-to-choose-an-iot-mqtt-broker/)

A practical 12-point checklist for choosing an IoT MQTT broker, a table of questions to ask every vendor, and a five-minute hands-on test you can run against broker.connectmq.com.

September 21, 20269 min read

MQTT Security

### [MQTT Security Best Practices: A 12-Point Checklist for IoT Teams](https://connectmq.com/blog/mqtt-security-best-practices/)

A hands-on MQTT security checklist covering TLS, credentials, client IDs, topic design, payload validation, rate limits and certificate checks, plus how ConnectMQ handles each point.

September 28, 202611 min read