---
title: "ConnectMQ Edge — PLC, Modbus & OPC UA to MQTT Gateway | ConnectMQ"
description: "ConnectMQ Edge collects data from Siemens S7, OMRON, Modbus, OPC UA, IEC 104 and IEC 61850 devices and sends it to MQTT over TLS, with an offline buffer."
url: "https://connectmq.com/connectmq-edge/"
language: "en"
---

ConnectMQ Edge

# From PLC to cloud, without writing a line of code

ConnectMQ Edge is a Windows gateway that collects data from PLCs, Modbus meters, protection relays, OPC UA servers and local brokers, sends it securely to your ConnectMQ broker in a clean ISA-95 topic structure, and keeps it on disk while the internet is down.

[Try it free](https://app.connectmq.com/signup) [See pricing](https://connectmq.com/pricing/)

No card required

-   Siemens S7 PLCs
-   OMRON PLCs
-   Modbus meters
-   IEC 104 RTUs
-   IEC 61850 IEDs
-   OPC UA servers

**ConnectMQ Edge**Windows service`ISA-95 · JSON``offline buffer`SCADA / HMI · OPC UA :48010 · MQTT :1883

**ConnectMQ Cloud**`broker.connectmq.com`Dashboards · Alerts · Digital Twin · API

-   10 drivers
-   Offline buffer
-   Local OPC UA & MQTT
-   Windows service

## Connect field devices without code

Pick a template — Siemens S7, OMRON, Modbus, OPC UA, IEC 104 or IEC 61850 — set the IP address and tags, and press Save and apply. The channel starts right away; the service does not restart.

## A clean ISA-95 topic tree

Every tag arrives as enterprise/site/area/line/cell/device/tag with a JSON payload — value, quality, unit and timestamp — ready for dashboards, alerts and the Digital Twin.

## Keeps data when the line drops

If the internet connection goes down, Edge buffers readings on disk and sends them to ConnectMQ Cloud when the link is back — no gaps in your history.

## Serves the plant locally, too

Everything Edge collects is also available on its own OPC UA server (:48010) and local MQTT broker (:1883), so SCADA, MES and historians read one endpoint instead of many protocols.

Local connectors

## Pick a connector to see how it works

Each connector has a step-by-step guide, an example configuration and the message that arrives in ConnectMQ Cloud.

### Read field devices

[**Siemens S7**S7-1200/1500, S7-300/400, S7-200 SMART and LOGO! over ISO-on-TCPLearn more](https://connectmq.com/connectmq-edge/siemens-s7/) [**Modbus TCP / RTU**Energy meters, drives and PLCs over Modbus TCP, UDP or RS-485 RTULearn more](https://connectmq.com/connectmq-edge/modbus/) [**OMRON FINS / NJ-NX**CJ/CP/CS memory areas over FINS and NJ/NX variables by nameLearn more](https://connectmq.com/connectmq-edge/omron/) [**OPC UA Client**Subscribe to any OPC UA server: S7-1500, Beckhoff, B&R, KEPServerEXLearn more](https://connectmq.com/connectmq-edge/opc-ua-client/) [**IEC 60870-5-104**RTUs and substation gateways as controlling station, port 2404Learn more](https://connectmq.com/connectmq-edge/iec-104/) [**IEC 61850 (MMS)**Protection relays, bay controllers and IEDs over MMS with SCL importLearn more](https://connectmq.com/connectmq-edge/iec-61850/)

### Serve and pass on locally

[**Sparkplug B**Ignition, Node-RED and Sparkplug gateways via the local brokerLearn more](https://connectmq.com/connectmq-edge/sparkplug-b/) [**Local OPC UA server**Every tag Edge collects on one OPC UA endpoint for SCADA and MESLearn more](https://connectmq.com/connectmq-edge/opc-ua-server/)

**All ten drivers**

-   Simulator
-   Modbus TCP
-   Modbus RTU
-   Siemens S7
-   OMRON FINS
-   OMRON NJ/NX
-   OPC UA Client
-   MQTT Client
-   IEC 60870-5-104
-   IEC 61850 (MMS)

Quick setup

## Up and running in six steps

1.  1
    
    ### Install
    
    Run the setup as administrator: one installer adds the Windows service and the desktop app.
    
2.  2
    
    ### Sign in
    
    Use your ConnectMQ account — Google, LinkedIn or e-mail.
    
3.  3
    
    ### Pick credentials
    
    Select the broker credential set Edge should use, if you have more than one.
    
4.  4
    
    ### Check status
    
    The tray icon turns green and the ONLINE strip shows the connection to ConnectMQ Cloud.
    
5.  5
    
    ### Add connectors
    
    Add a channel per PLC, meter or server from a template — or start with the Simulator for a quick test.
    
6.  6
    
    ### Use the data
    
    The topics appear in the ConnectMQ portal, ready for dashboards, alerts and the Digital Twin.
    

## Get ConnectMQ Edge

ConnectMQ Edge is included in the Basic and Scale plans. Sign in to the ConnectMQ portal and download the installer from the ConnectMQ Edge page in your account menu.

-   Windows 10 / 11 · Windows Server 2016+ (x64)
-   Windows service + desktop app, one installer
-   Sign in with your ConnectMQ account

## ConnectMQ Edge: frequently asked questions

What is ConnectMQ Edge?

A Windows gateway that runs next to your machines. It reads PLCs, meters, relays and OPC UA servers, turns the values into MQTT messages in an ISA-95 topic tree and sends them to your ConnectMQ broker over TLS.

What happens when the internet connection drops?

Edge keeps collecting and stores the readings on disk. When the connection is back, the buffered data is sent to ConnectMQ Cloud, so your history has no gaps.

Can my local SCADA read the data too?

Yes. Edge runs its own OPC UA server on port 48010 and a local MQTT broker on port 1883. Local SCADA, HMI, MES or historians can read every tag from Edge without going through the cloud.

Which plans include ConnectMQ Edge?

ConnectMQ Edge is included in the Basic and Scale plans. You download it from your ConnectMQ account after signing in.

## Connect your first PLC this week

Create your ConnectMQ account, download ConnectMQ Edge from the portal and add your first connector in minutes.

[Get started](https://app.connectmq.com/signup) [See pricing](https://connectmq.com/pricing/)

## Articles

[All articles](https://connectmq.com/blog/)

Industrial IoT

### [Sparkplug B and the Unified Namespace: Structuring Industrial IoT Data on MQTT](https://connectmq.com/blog/mqtt-sparkplug-b-unified-namespace/)

Sparkplug B gives industrial MQTT a strict session and payload model, while a Unified Namespace gives your plant data a single, readable home. Here is how they fit together, with topic design tips and live examples.

August 26, 20269 min read

Managed MQTT Cloud

### [How to Choose an IoT MQTT Broker: 12 Criteria and the Questions to Ask Your Vendor](https://connectmq.com/blog/how-to-choose-an-iot-mqtt-broker/)

A practical 12-point checklist for choosing an IoT MQTT broker, a table of questions to ask every vendor, and a five-minute hands-on test you can run against broker.connectmq.com.

September 21, 20269 min read

MQTT Security

### [MQTT Security Best Practices: A 12-Point Checklist for IoT Teams](https://connectmq.com/blog/mqtt-security-best-practices/)

A hands-on MQTT security checklist covering TLS, credentials, client IDs, topic design, payload validation, rate limits and certificate checks, plus how ConnectMQ handles each point.

September 28, 202611 min read
