---
title: "IEC 61850 (MMS) to MQTT — ConnectMQ Edge Connector | ConnectMQ"
description: "Connect IEC 61850 relays and IEDs to MQTT: ConnectMQ Edge reads MMS data, enables buffered and unbuffered reports, sends controls and imports SCL files."
url: "https://connectmq.com/connectmq-edge/iec-61850/"
language: "en"
---

ConnectMQ Edge · IEC 61850 (MMS)

# Protection relays and IEDs, live in the cloud

Relay and IED data often sits behind the station HMI, out of reach for the rest of the business. ConnectMQ Edge reads IEC 61850 data over MMS, maps whole bays from an SCL file and uses reports so changes arrive immediately. The values land on your ConnectMQ broker as ISA-95 JSON, ready for dashboards, alerts and the Digital Twin.

-   MMS · port 102
-   SCL import (ICD / CID / SCD)
-   Reports & controls

[Try it free](https://app.connectmq.com/signup) [See pricing](https://connectmq.com/pricing/)

No card required

-   Siemens S7 PLCs
-   OMRON PLCs
-   Modbus meters
-   IEC 104 RTUs
-   IEC 61850 IEDs
-   OPC UA servers

**ConnectMQ Edge**Windows service`ISA-95 · JSON``offline buffer`SCADA / HMI · OPC UA :48010 · MQTT :1883

**ConnectMQ Cloud**`broker.connectmq.com`Dashboards · Alerts · Digital Twin · API

## Why connect IEC 61850 (MMS) to ConnectMQ

### Map a bay from its SCL file

Point Edge at the ICD, CID or SCD file and a tag is created for every ST/MX data object — or let Edge browse the IED online.

### Reports instead of polling

Buffered and unbuffered reports deliver changes the moment they happen, instead of waiting for the next poll.

### Clean data, even offline

Values reach ConnectMQ as ISA-95 JSON with quality, unit and timestamp, and are buffered on disk while the internet is down.

## What it reads and does

-   Protection relays, bay controllers and other IEDs over MMS (port 102)
-   Automatic tags from SCL files (ICD/CID/SCD) or online browsing
-   Buffered and unbuffered report control blocks
-   Controls on \[CO\] addresses following the IED’s ctlModel, including SBOw
-   Scale and unit conversion, for example W to kW

What arrives in ConnectMQ Cloud`connectmq/site1/substation/bay1/Feeder1/TotW`

```
{ "value": 842.5, "quality": "good", "unit": "kW", "dataType": "Float32", "tag": "TotW", "device": "Feeder1", "channel": "Relays" }
```

## Up and running in three steps

1.  1
    
    ### Install ConnectMQ Edge
    
    Download Edge from your ConnectMQ account and sign in — the Windows service and desktop app come in one installer.
    
2.  2
    
    ### Add the IEC 61850 (MMS) channel
    
    Pick the IEC 61850 (MMS) template, enter the address of your device and the tags you need, and press Save and apply.
    
3.  3
    
    ### Use the data
    
    The tags appear in your ConnectMQ broker as ISA-95 topics, ready for dashboards, alerts and the Digital Twin.
    

## Where teams use it

### Relay and breaker status at a glance

Status and measurements from every bay in one ConnectMQ dashboard, with alerts on trips and alarms.

### Power measurements per feeder

Publish MMXU measurements such as total active power to follow the load of each feeder and site over time.

### Substation in the Digital Twin

Bind IED values to the ConnectMQ 3D Digital Twin so operators and engineers see the live state of each bay.

## IEC 61850 (MMS): frequently asked questions

How do I connect an IEC 61850 protection relay to MQTT?

Install ConnectMQ Edge on a Windows PC that reaches the IED on port 102, add an IEC 61850 (MMS) channel, enter the IP address and, if you have it, the SCL file, and press Save and apply. Edge publishes the data objects to your ConnectMQ broker over MQTT/TLS as ISA-95 topics with JSON payloads.

Do I need the SCL file of the IED?

No. With an SCL file (ICD, CID or SCD) and "AutoCreateTags": true, Edge creates a tag for every ST/MX data object. Without an SCL file it browses the IED online.

Does ConnectMQ Edge support IEC 61850 reports and controls?

Yes. Edge enables buffered and unbuffered reports that you list under Reports, so changes arrive without polling. Controls on \[CO\] addresses follow the IED’s ctlModel, including SBOw.

Technical details: step-by-step setup and example configuration

### Set it up step by step

1.  1
    
    Get the IED IP address (port 102) and, if you have it, the SCL file of the IED. Copy the SCL file into %ProgramData%\\ConnectMQ\\Edge\\scl\\.
    
2.  2
    
    In ConnectMQ Edge open Connectors in the left menu, click + Add channel and pick the IEC 61850 (MMS) template.
    
3.  3
    
    The channel is added with sample addresses. In the editor on the right, change the IP address, device settings and tags to match your equipment — the example configuration shows the format. Validate project checks it.
    
4.  4
    
    Press Save and apply. The channel starts right away without restarting the service. Add as many channels as you need, including several of the same type.
    
5.  5
    
    With "SclFile" and "AutoCreateTags": true a tag is created for every data object (ST/MX); without an SCL file the IED is browsed online.
    
6.  6
    
    Add report control blocks under Reports so that changes arrive immediately instead of by polling. Controls (\[CO\] addresses) follow the IED’s ctlModel, including SBOw.
    
7.  7
    
    Check the result: on Overview the devices show Reading data under Field devices, and problems (wrong address, timeout, rejected login) appear in the Last problem column. The values are in Local OPC UA Server › Live tag values; details are in Windows Service Settings › Logs.
    
8.  8
    
    Open the ConnectMQ portal: the tags appear in the topic tree as <enterprise>/<site>/<area>/<line>/<cell>/<device>/<tag> with a JSON payload (value, quality, unit, timestamp), ready for dashboards, alerts and the Digital Twin.
    

Example configuration

```
{
  "Name": "Relays",
  "Driver": "Iec61850",
  "Devices": [{
    "Name": "Feeder1",
    "Isa95": { "Area": "substation", "Line": "bay1" },
    "Settings": {
      "Host": "192.168.10.21",
      "IedName": "REL1",
      "SclFile": "scl/relay1.cid",
      "AutoCreateTags": true,
      "Reports": [{ "Rcb": "LD0/LLN0.BR.brcbST01" }]
    },
    "Tags": [
      { "Name": "TotW", "Address": "LD0/MMXU1.TotW[MX]", "DataType": "Float32", "Scale": 0.001, "Unit": "kW" }
    ]
  }]
}
```

### Good to know

-   Put SCL files in %ProgramData%\\ConnectMQ\\Edge\\scl\\ and reference them relative to that folder, as in "SclFile": "scl/relay1.cid".
-   Without report control blocks the values are polled; add them under Reports (for example LD0/LLN0.BR.brcbST01) to get changes immediately.
-   Controls on \[CO\] addresses follow the ctlModel configured in the IED, including select-before-operate with value (SBOw).
-   Use Scale and Unit to convert values, as in the example: TotW in W with "Scale": 0.001 is published in kW.

## Other connectors

[**Siemens S7**S7-1200/1500, S7-300/400, S7-200 SMART and LOGO! over ISO-on-TCPLearn more](https://connectmq.com/connectmq-edge/siemens-s7/) [**Modbus TCP / RTU**Energy meters, drives and PLCs over Modbus TCP, UDP or RS-485 RTULearn more](https://connectmq.com/connectmq-edge/modbus/) [**OMRON FINS / NJ-NX**CJ/CP/CS memory areas over FINS and NJ/NX variables by nameLearn more](https://connectmq.com/connectmq-edge/omron/) [**OPC UA Client**Subscribe to any OPC UA server: S7-1500, Beckhoff, B&R, KEPServerEXLearn more](https://connectmq.com/connectmq-edge/opc-ua-client/) [**IEC 60870-5-104**RTUs and substation gateways as controlling station, port 2404Learn more](https://connectmq.com/connectmq-edge/iec-104/) [**Sparkplug B**Ignition, Node-RED and Sparkplug gateways via the local brokerLearn more](https://connectmq.com/connectmq-edge/sparkplug-b/) [**Local OPC UA server**Every tag Edge collects on one OPC UA endpoint for SCADA and MESLearn more](https://connectmq.com/connectmq-edge/opc-ua-server/)

[ConnectMQ Edge](https://connectmq.com/connectmq-edge/)

## Connect your first PLC this week

Create your ConnectMQ account, download ConnectMQ Edge from the portal and add your first connector in minutes.

[Get started](https://app.connectmq.com/signup) [See pricing](https://connectmq.com/pricing/)

## Articles

[All articles](https://connectmq.com/blog/)

Industrial IoT

### [Sparkplug B and the Unified Namespace: Structuring Industrial IoT Data on MQTT](https://connectmq.com/blog/mqtt-sparkplug-b-unified-namespace/)

Sparkplug B gives industrial MQTT a strict session and payload model, while a Unified Namespace gives your plant data a single, readable home. Here is how they fit together, with topic design tips and live examples.

August 26, 20269 min read

Managed MQTT Cloud

### [How to Choose an IoT MQTT Broker: 12 Criteria and the Questions to Ask Your Vendor](https://connectmq.com/blog/how-to-choose-an-iot-mqtt-broker/)

A practical 12-point checklist for choosing an IoT MQTT broker, a table of questions to ask every vendor, and a five-minute hands-on test you can run against broker.connectmq.com.

September 21, 20269 min read

MQTT Security

### [MQTT Security Best Practices: A 12-Point Checklist for IoT Teams](https://connectmq.com/blog/mqtt-security-best-practices/)

A hands-on MQTT security checklist covering TLS, credentials, client IDs, topic design, payload validation, rate limits and certificate checks, plus how ConnectMQ handles each point.

September 28, 202611 min read
